(close this window to return to the Performance page)
![](files/profile_sep_analysis.jpg)
- The red lines in this image show the actual energy generated during a cloudless day near the autumnal equinox. The area under this curve corresponds to 15.6 kWh.
- The dashed yellow lines (from left to right) indicate 9:30am (when the shadow of the dormer left the panels on the west side), 1pm (when the sun was due south), and 4:30pm (when the tree's shadow reached the roof).
- The black curve represents my theoretical estimate of the energy that could have been generated under ideal, unshaded conditions. The area under this curve corresponds to 17.6 kWh.
Summary:
Condition | Energy | Percent of Theoretical |
Theoretical | 17.6 kWh | 100% |
Actual | 15.6 kWh | 88.7% |
Dormer Shading (morn + eve) | 0.7 kWh | 3.7% |
Maple Tree Shading | 0.3 kWh | 1.5% |
Flat-top Effect | 1.1 kWh | 6.1% |