Max Power (MP) 200 W (STC), 142 W (NOC) MP Voltage 26.3 V (STC), 23.2 V (NOC) MP Current 7.61 A (STC), 6.13 A (NOC) Open Circuit Voltage 32.9 V (STC), 29.9 V (NOC) Short Circuit Current 8.21 A (STC), 6.62 A (NOC) Standard Test Conditions (STC) 1000 W/m2 irradiance, 25 deg C cell temperature, and AM1.5 spectrum Nominal Operating Conditions (NOC) 800 W/m2 irradiance, 47 deg C cell temperature, and AM1.5 spectrum Length x Width 56.2 in x 39.0 in
Max Power (MP) 130 W (STC), 92 W (NOC) MP Voltage 17.6 V (STC), 15.5 V (NOC) MP Current 7.39 A (STC), 5.94 A (NOC) Open Circuit Voltage 21.9 V (STC), 19.9 V (NOC) Short Circuit Current 8.02 A (STC), 6.47 A (NOC) Length x Width 56.1 in x 25.7 in
Each side: eight KC200GT and two KC130 GT in series
Total array: east side and west side tracked independently by inverter
|
< West Side | East Side > |
SolarMount Light rails (no longer available, but Standard is very similar)
Serrated L-feet (to attach rails to roof)
Top Mounting Clamps and T-bolts (to attach panels to rails)
Part # SD780 (no longer available, but SD783 is very similar)
Model 0780 GRY (primer gray)
Two Square D Heavy Duty Safety Switches
600 VDCOne Square D General Duty Safety Switch
30 A
Model HU361
240 VAC
60 A
Model D222N
with 20A Class R fuse (FRN-R) on each of the two hot lines